2.4.2 Timer and Counter
EEPROM LE93C46 (IC12) on the main board stores certain counter and timer values used for
controllingink system operation.
2.4.2.1 ProtectCounter
Protect counter A and Ink Amount Counter R values are stored in the EEPROM on the main
board,and while the printeris on, this data is saved in the RAM on the main board.
❏ProtectCounter A This counter is used to manage the total amount of drained ink. If
the counter value is equal toor exceeds 51000, the printer indicates
an error on the control panel and maintenance is required. This
counter is incremented by the following every sequence. (Values
inparentheses ( )mean only the color head. 1point = 0.025 cc.)
1.Power On
(Micro): 40 steps ×6 (5) 2points
40 steps ×10 (9) 3points
40 steps ×15 (12) 5(4) points
2.CL 1: 3600 (4800) steps 16 (20) points
40 steps ×12 absorption 4 points
3.CL 2: 720 steps 4points
7800 (8200) steps 40 points
40 steps ×12 4points
4.CL 3 : 40steps ×12 4points
5.I/C Replacement: 8900 (14000) steps 48(72) points
8900 (8800) steps 48 (44) points
40 steps ×12 4points
6.Fixed time
FalseAbsorption: Monochromeand CMY = 2
7.Power On
(Normal): 3600 (4800) steps 16 (20) points
40 steps ×12 4points
Note for ServiceAlso, protect counter A resets when:
1. The printer is shipped from the factory.
2. After the maintenance is performed.
(When the ink drain tank (ink-eject porous pad, part number 130) is replaced.)
Stylus Pro XL Operating Principles
REV.-A 2-27