Connection cannot be established in access point mode or wired LAN connection mode
Connection is not possible in easy connection mode (ad hoc modeg)
Is the computer's radio wave setting for the
wireless LAN set to low-intensity?
Change the radio wave setting to the highest possible intensity.
Is the LAN card you are using 802.11g or
802.11b compliant?
Only 802.11g or 802.11b compliant equipment can be used. You cannot use equipment conforming
to any other standards (such as 802.11 or 802.11a).
Is WEPg encryption set to "ON" at the
computer?
If using easy connection mode (ad hoc modeg), WEP must be set to "OFF", otherwise connection
will not be possible. Set WEP encryption to "OFF". s"Connecting Using Easy Connect Mode
(Wireless LAN)" in the EasyMP Network Setup Guide
Check Remedy
Is the ESSIDg setting correct? Enable the automatic ESSID search function, or set the ESSID for the computer or access point and
the projector so that they are the same. s"Connecting in Access Point Mode or Wired LAN
Mode" in the EasyMP Network Setup Guide
Has an identical WEPg key been set? If "WEP" is selected in the "Security" configuration menu, set the WEP key for the computer or
access point and the projector to the same key. s"Connecting in Access Point Mode or Wired
LAN Mode" in the EasyMP Network Setup Guide
Are the connection refusal functions of the
access point, such as the MAC addressg and
port restrictions, set correctly?
Set the projector connection permissions on the access point.
Have the IP addressg, subnet maskg and
gatewayg address for the access point and
the projector been set correctly?
If not using DHCPg, make all of the settings manually.
s"Connecting in Access Point Mode or Wired LAN Mode" in the EasyMP Network Setup Guide
Have the same subnet masks been set for the
access point and the projector?
Select "Use IP connect mode" in EMP NS Connection and connect using IP connect mode.
s"If No Connected Projectors Appear" in the EasyMP Operation Guide
Check Remedy
Is there an access point manufactured by
BUFFALO operating nearby?
Ad hoc connection is not possible if there is a BUFFALO access point set to the same ESSIDg,
operating nearby. Turn off the power to the Melco access point or select an ESSID different to that
access point.