2.8 FAQ
2.8.1Q1. The printer does not operate correctly. ("Serial interface" is printed by the self test for the printer.)
2.8.1.1A1. For TM-T90, TM-L90, TM-J2000, TM-J2100, TM-J7000, TM-J7100, TM-J7500, and TM-J7600, set the #25 pin reset signal of the Memory switch set to disabled. For other models, use the printer with the #31 pin reset signal of the DIP switch for parallel interface enabled.
Model | Setting |
| |
TM-U200 Series | DIP SW 2-8: ON |
| |
TM-U210 Series | DIP SW 2-8: ON |
| |
TM-U220 Series (STD) *1 | DIP SW2-8: ON |
| |
TM-U220 Series (US) *1 | DIP SW2-4: ON |
| |
TM-U230 Series | DIP SW 2-4: ON |
| |
TM-U325 Series | DIP SW 2-8: ON |
| |
TM-U590 Series | DIP SW 2-8: ON |
| |
TM-U675 Series | DIP SW 2-8: ON |
| |
TM-T88/T88II/T88III | DIP SW 2-8: ON |
| |
TM-T90 | MSW 1-8: ON |
| |
TM-H5000/H5000II | DIP SW 2-8: ON |
| |
TM-H6000/H6000II | DIP SW 2-8: ON |
| |
TM-J7000/J7100 | MSW 1-8: ON |
| |
TM-J7500/J7600 | MSW 1-8: ON |
| |
TM-J2000/J2100 | MSW 1-8: ON |
| |
TM-L90 | MSW 1-8: ON |
| |
*1 TM-U220 has two DIP switch pattern. See TM-U220 Technical Reference Guide for detail.
2.8.2 Q2. The self test does not operate correctly.
2.8.2.1A2. Turn on the printer power while pressing the FEED button and hold the Feed button until printing starts to perform the self test for the printer with the UB-E02. Printing starts in approximately 6 seconds when the IP address is fixed or approximately 13 seconds when the IP address is acquired by auto setting. (It can be longer, depending on the reply time of the host.)
2.8.3 Q3. Starting up the printer takes a long time.