5.5.5.2 Internal Parameter Setting Methods

1.Using the exclusive utility.

2.Using a browser

3.Using arp and ping commands (only to set IP address)

5.5.5.3 Setting with Exclusive utility

Settings cannot be made by the specified application software when the ENPC protocol is used. A dedicated utility which can set miscellaneous with the ENPC protocol is provided by EPSON.

5.5.5.4 Setting with Browser

Setting can be made by an HTTP browser when connected to the module. The new IP address takes effect when the printer power is turned off and back on.

5.5.5.5 Setting the IP Address with arp + ping

This function is available when it has been enabled.

The setting can be made from a host in the same segment as the module. The host must support both arp and ping commands.

The new IP address takes effect when the module responds to the ping command.

Example-1: using SunOS

arp -s 123.456.789.123 00:00:48:06:00:01 temp ping 123.456.789.123

Example-2: using Windows

arp -s 123.456.789.123 00-00-48-06-00-01 ping 123.456.789.123

5.5.5.6 How to check the Mac Address

The Mac address of the UB-E02 can be checked with any of the following methods:

Printing the status sheet

Checking the label on the UB-E02

Checking the HTTP browser

Checking the printer self-test (however, the self-test function is limited for each model.)