7.Reinstall the developer cartridge.

8.Press down the printer cover until it clicks shut.

9.When turning on the printer, access the printer settings dialog box in the printer driver, and click the OPC Level Clear button. The OPC level clear dialog box is displayed.

10.Click OK to reset the Photoconductor level counter.

Cleaning the Printer

The printer needs only minimal cleaning. If you notice a decline

in print quality, clean the inside of the printer as described in this 5 section.

You should also clean the paper cassette and the printer cover every few months. These procedures are described later in this section.

Cleaning the inside of the printer

Fine particles of dust can collect inside the printer. Follow the steps below to clean the inside of the printer and the paper feeder:

1.Make sure the printer is turned off.

2.Open the printer cover.

w Warning:

Opening the printer exposes the fuser, which is marked CAUTION Hot Surface Avoid Contact.

3.Remove the developer cartridge and the photoconductor unit as each are described in “Replacing Consumable Products” on page 5-2.

Maintenance and Transportation

5-9