The physical distance of the offset lengths and scanning lengths depends on the current dpi and zoom settings. For example, when the main scan and sub scan lengths are set to 400 dots and 640 dots respectively (at 100 dpi and 100%), the physical lengths are 4 inches (10.16 cm) and 6.4 inches (16.26 cm) respectively.

Relation to other commands

The reading area is reset to the maximum value when the

ESC R (Set resolution) command or ESC H (Set zoom) command settings are made. Make those settings before the scanning area is specified.

The scanning length determines the number of pixels (dots) to be read. The actual image data can vary from 1 bit per pixel to 8 bits per pixel according to the data format setting made with the ESC D command.

The main scan value should always be specified as a number that is a multiple of 8. The offset lengths can be any integer value.

3-32Command Reference