Determining setting values after trimming
After trimming an image, you should resend the ESC A command using the following parameters.
| ⎛n1 | × RX2 × HX2⎞ |
|
|
|
| ||||||
N1 | = INT ⎜ |
|
|
|
|
| ⎟ |
|
|
|
| |
| RX1 × HX1 |
|
|
|
|
|
| |||||
| ⎝ |
|
| ⎠ |
|
|
|
| ||||
| ⎛n2 | × RY2 × HY2 | ⎞ |
|
|
|
| |||||
N2 | = INT ⎜ |
|
|
|
| ⎟ |
|
|
|
| ||
| RY1 × HY1 |
|
|
|
|
| ||||||
| ⎝ |
| ⎠ |
|
|
|
| |||||
|
|
| ⎛⎛n3 × RX2 | × HX2 | ⎞ |
| 1 | ⎞ | ||||
N3 | = 8 × INT ⎜⎜ |
|
|
|
| ⎟ | × | 8 | ⎟ | |||
RX1 × | HX1 | |||||||||||
|
|
| ⎝⎝ | ⎠ |
| ⎠ | ||||||
| ⎛n4 | × RY2 × HY2 | ⎞ |
|
|
|
| |||||
N4 | = INT ⎜ |
|
|
|
| ⎟ |
|
|
|
| ||
| RY1 × HY1 |
|
|
|
|
| ||||||
| ⎝ |
| ⎠ |
|
|
|
|
⎛(maximum main scan length) |
| RX × HX ⎞ | |||
N1 + N3 ≤ INT ⎜ |
| × |
|
| ⎟ |
(maximum resolution ) | 100 |
| |||
⎝ |
| ⎠ |
⎛(maximum sub scan length) |
| RY × HY ⎞ | |||
N2 + N4 ≤ INT ⎜ |
| × |
| ⎟ | |
(maximum resolution ) | 100 | ||||
⎝ |
| ⎠ |
The parameters for the ESC R, ESC H, and ESC A command should be set to the following.
ESC R : n1 = RX2, n2 = RY2
ESC H : i1 = HX2, i2 = HY2
ESC A : n1 = N1, n2 = N2, n3 = N3, n4 = N4