Software Functions and Settings

The function level of the GT-1000 is B2. The table below lists the functions and settings that can be controlled with software commands.

Function

Available settings

 

 

Output resolution

3 settings (50, 100, 200 dpi)

 

 

Zoom

50% to 200% in 10% increments

 

 

Reading area

592 × 840 dots at 200 dpi, 100%

 

 

Data format

1 to 8 bits per pixel per color

 

 

Color mode

color (page sequence),

 

monochrome (standard and with dropout color)

 

 

Brightness

7 levels

 

 

Halftoning mode

3 modes

 

 

Gamma correction

5 settings

 

 

Software Defaults

With the DIP switches at the preset factory settings, the following values are the default values on the GT-1000 when the power is turned on.

Function

Command

Default value

 

 

 

Data format

ESC D

i=01H (1 bit/pixel/color)

 

 

 

Resolution

ESC R

n1=100, n2=100 (dpi)

 

 

 

Zoom

ESC H

i1=100, i2=100 (%)

 

 

 

Reading area

ESC A

n1=0, n2=0, n3=296, n4=420 (dot)

 

 

 

Color mode

ESC C

i=00H (monochrome)

 

 

 

Brightness

ESC L

BRIGHTNESS dial setting

 

 

 

Gamma correction

ESC Z

i=01H (CRT Display A)

 

 

 

Halftoning mode

ESC B

i=00H (Halftoning Mode A)

 

 

 

Scanner Model Technical Data B-3