Software Defaults
With the DIP switches at the preset factory settings, the following values are the default values on the
Function | Command | Default value |
|
|
|
Data format | ESC D | i=01H (1 bit/pixel/color) |
|
|
|
Resolution | ESC R | n1=100, n2=100 (dpi) |
|
|
|
Zoom | ESC H | i1=100, i2=100 (%) |
|
|
|
Reading area | ESC A | n1=0, n2=0, n3=856, n4=1160 (dot) |
|
|
|
Color mode | ESC C | i=00H (standard monochrome) |
|
|
|
Brightness | ESCL | i=00H (center) |
|
|
|
Gamma correction | ESC Z | i=01H (CRT Display A) |
|
|
|
Halftoning mode | ESC B | i=00H (Halftoning Mode A) |
|
|
|
Color correction | ESC M | i=80H (CRT Display) |
|
|
|
Note:
The default values for the ESC B, ESC Z, and ESC M commands are affected by DIP switch settings.
Scanner Model Technical Data