3 INSTRUCTION SET

RCF

Reset carry flag

 

Source Format:

RCF

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation:

C

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OP-Code:

1

 

1

1

1

0

1

0

1

1

1

1

0

 

F5EH

 

MSB

 

 

 

 

 

 

 

 

 

 

LSB

 

Type: VI

Clock Cycles: 7

Flag: C – Reset

Z– Not affected D – Not affected I – Not affected

Description: Resets the C (carry) flag.

Example:

 

ADD A,4

 

 

RCF

 

A register

1101

 

0001

0001

 

C flag

0

 

1

0

RDF

Reset decimal flag

 

Source Format:

RDF

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation:

D

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OP-Code:

1

 

1

1

1

0

1

0

1

1

0

1

1

 

F5BH

 

MSB

 

 

 

 

 

 

 

 

 

 

LSB

 

Type: VI

Clock Cycles: 7

Flag: C – Not affected

Z– Not affected D – Reset

I – Not affected

Description: Resets the D (decimal) flag.

Example:

 

ADD A,8

 

RDF

 

LD A,6

 

 

ADD A,8

 

A register

0110

 

0100

 

0100

 

0110

 

1110

 

D flag

1

 

1

 

0

 

0

 

0

 

C flag

0

 

1

 

1

 

1

 

0

 

Z flag

0

 

0

 

0

 

0

 

0

72

EPSON