Compressor Connecting Pins Location
The following procedure should be used
Evacuation with Recovery of Refrigerant
Pinch the charging pipe with pliers. Remove the service valve and solder the hole together
Page 1
Image 1
SERVICE MANUAL
(TROUBLE SHOOTING AND REPAIRING TIPS)
Fourth Edition – February 2006
CONSERV REFRIGERATOR
MODELS
375 / 1200 SERIES ( OLD & NEW)
Page 2
Page 1
Image 1
Page 2
Contents
Fourth Edition – February
TROUBLE SHOOTING AND REPAIRING TIPS
CONSERV REFRIGERATOR
MODELS
Page
WARRANTY
WARRANTY INFORMATION
WARRANTY SERVICE
EXCLUSIONS
Page
Disturbance
Trouble-Shooting
Cause
Remedy
Caus e
D is turbance
Trouble -Shooting
R e me dy
Disturbance
Troubleshooting
Cause
Remedy
Ditrubance
Trouble-shooting
Cause
Remedy
Disturbance
Trouble-shooting
Cause
Remedy
Trouble -shooting
D isturbance
R e me dy
Cause
1.2. Trouble-Shootingin the Electric Circuit
1.4. Compressor Failure
1.3. Checking for Leakage to Frame
Danfoss Compressors Za nussi Compressors
Compressor Connecting Pins Location
Unidad Hermética Compressors
Universal PTC Starting Device
1.6. The PTC Starting Device
The HST Starting Device
1.7. Using a Manometer in Trouble-Shooting
1. The system is blocked
The Possibility of Fire/Explosion exists
2.MAKING REPAIRS TO THE REFRIGERATING SYSTEM
First Evacuation
The Blowing Process
Filling of R600a
Actual Evacuation
4.Mount the hose on the vacuum pump outlet
7.Drilling and tapping of the process pipe
Actual Evacuation and Filling of R600a
Close the valve
Pinch the charging pipe with pliers. Remove the service valve and solder the hole together
Evacuation with Recovery of Refrigerant
7.Drilling and tapping of process pipe
Opening the System
8.Connect dry nitrogen and equalize the pressure
from Refrigerant Bag
3.Recovery
1.Service Tools
2.1.3.Opening the Refrigerating System with
Refrigerant R134a for Repairs
2.2. Replacing the Filter Drier
The following procedure should be used
Capillary tube broken off without the use of special-purposepliers
2.3. Replacing the Compressor
The following procedure is to be used
Dismounting
2.4.Replacing the Evaporator
Mounting
2.5. Replacing the Thermostat Uprights
Installing the Thermostat Phial
Chest freezers
Uprights with curved doors