Equator 375 service manual D isturbance, Trouble -shooting, R e me dy, Cause

Models: 375

1 33
Download 33 pages 23.21 Kb
Page 10
Image 10
D isturbance

D isturbance

Cause

Trouble -shooting

R e me dy

 

Unit has recently been

Q uestion user about use

Inform user about the

 

filled with large

of unit immediately prior

problems caused by this.

 

quantities of food.

to service call.

Instruct user about use of

 

 

 

fast-freeze switch.

 

Built-in thermometer

Check for correct

Replace built-in

 

is defective. User’s

thermometer readings.

thermometer if necessary.

 

thermometer is

 

 

 

defective.

 

 

 

Ambient temperature

Symptoms resemble those

Find a more suitable

 

is below 0°C.

of partially blocked

location for the unit, with

 

refrigerant has

capillary tube. Record

higher ambient

 

collected in the

ambient temperature.

temperature.

 

condenser.

 

 

 

Ambient temperature

Compare exact

Arrange for better

 

is too high, possibly

temperature with user’s

location of unit and/or

 

because unit is too

observations. Check air

better ventilation.

 

close to a heat

circulation.

 

 

source, or ventilation

 

 

 

is insufficient.

 

 

Compressor runs

Doors do not fit

Insert paper between

Fold double-sided tape to

continuously.

snugly.

door and frame and

suitable thickness and

 

 

closed door. If paper can

press in between gasket

 

 

be pulled out without

and door. Pull gently in

 

 

resistance, the door does

gasket at relevant area.

 

 

not fit tightly enough.

 

 

 

 

 

Rapid ice formation

As above.

As above.

As above.

on freezer shelves.

 

 

 

 

 

 

 

Insufficient

User wishes to lower

Measure the exact

The cut-out temperature

refrigeration.

temperature in unit.

temperature.

can be lowered by giving

 

 

 

the thermostat phial a

 

 

 

reduced surface contact

 

 

 

with the aluminum

 

 

 

evaporator (refer to

 

 

 

automatic defrosting

 

 

 

section).

 

 

 

 

Automatic defrosting

The cut-in

Measure temperature at

Increase the cut-in

does not function.

temperature of the

phial. Temperature here

temperature of the

Possibly due to ice

thermostat is too low.

must not be lower than the

thermostat by giving the

formation on

The thermostat phial

cut-out temperature. See

phial a greater surface

evaporator.

has insufficient surface

Section 2.

contact with the

 

contact with the

 

evaporator. If this does

 

evaporator.

 

not help, replace the

 

 

 

thermostat.

 

 

 

 

8.

Page 10
Image 10
Equator 375 service manual D isturbance, Trouble -shooting, R e me dy, Cause