Equator 375 service manual Disturbance, Cause, Remedy, Trouble-ShootingChart

Models: 375

1 33
Download 33 pages 23.21 Kb
Page 5
Image 5

1.1 Trouble-Shooting Chart

Disturbance

Cause

Trouble-Shooting

Remedy

Unit does not

Wall socket is dead.

Check installation.

Install new fuse if

refrigerate or freeze,

 

 

necessary. Inform user.

compressor does not

 

 

 

operate.

 

 

 

 

 

 

 

 

Mains cable is

See section 1.2: Trouble-

Repair or replace socket

 

defective.

shooting in the electrical

or mains cable.

 

 

circuit.

 

 

 

 

 

 

Thermostat is

 

Replace thermostat.

 

defective.

 

 

 

 

 

 

 

Defective winding in

See section 1.6: Trouble-

Replace compressor.

 

compressor.

shooting for Electrical

 

 

 

Faults in the Compressor.

 

 

 

 

 

 

Starting device is

See section 1.2: trouble

Replace starting device.

 

defective.

shooting in the Electric

 

 

 

circuit.

 

 

Wiring for starting

 

Correct in accordance

 

device is incorrectly

 

with wiring diagram in

 

installed.

 

the spare parts list.

 

 

 

 

No-Frost

Timer is set in

 

Turn timer knob past

 

defrosting position.

 

defrosting.

 

 

 

 

Unit does not

Insufficient mains

Check mains voltage.

Inform user that

refrigerate or freeze,

voltage.

 

installation should be

compressor tries to

 

 

repaired by an electrician.

start but fails to

 

 

 

operate.

 

 

 

 

Wrong or defective

See section 1.2:

Install new starting

 

starting device.

Troubleshooting in the

device.

 

 

Electric Circuit.

 

 

Wiring for starting

 

Correct according to

 

device is incorrectly

 

wiring diagram in the

 

installed.

 

spare parts list.

 

 

 

 

 

Winding fault in

See section 1.5:

Replace compressor.

 

compressor.

Troubleshooting for

 

 

 

Electrical Faults in the

 

 

 

compressor.

 

 

 

 

 

 

Condensing pressure

Open system and location

Remove filter drier and

 

too high (obstruction

obstruction by blowing

cut 5 cm of the capillary

 

capillary tube).

N2 through system. See

tube. Blow through the

 

 

Section 2.1: Opening the

system thoroughly before

To be continued on

 

Refrigerating System with

installing new filter.

the next page

 

R600a for Repairs.

 