Equator 375 service manual Uprights with curved doors

Models: 375

1 33
Download 33 pages 23.21 Kb
Page 33
Image 33
Uprights with curved doors

Positioning of the Thermostat Phial in NFG 307 from Serial No. 501-----

In order to ensure the proper functioning of the thermostat 90

mmof the free end of the capillary tube is to serve as thermostat phial.

In case of failing thermostat functioning and a possible replacement of the thermostat, be sure that the phial part is placed sufficiently far into the cabinet. This can be done visually by removing the air duct.

Uprights with curved doors

Dismount the phial tube and straighten out the phial. Draw off the insulation, if any, around the phial.

After the plug has been removed from the socket, remove the cover for the top panel and the electrical unit simultaneously. Remove the thermostat knob, nut and thermostat wiring and draw the phial out of the mounting pipe behind the electrical unit.

Install the new thermostat in reverse order.

31.

Page 33
Image 33