e)If the coolant level is low, remove the cap to the overflow bottle and fill to the indicator line. Use coolant specified in Section 2.5.2.

NOTE: Units should only be filled with Dex-Cool© extended life coolant, which can be identified by its orange color.

WARNING

POTENTIAL HAZARD

Engine coolant is hot and pressurized.

Radiator and surrounding parts are hot.

WHAT CAN HAPPEN

Spray or steam from hot, pressurized liquid in the engine cooling system and touching a hot radiator may cause severe burns.

HOW TO AVOID THE HAZARD

Allow the engine to cool completely before removing the radiator cap or servicing any component of the cooling system.

CAUTION

POTENTIAL HAZARD

Engine coolant is toxic.

WHAT CAN HAPPEN

Swallowing coolant can cause poisoning.

HOW TO AVOID THE HAZARD

Do not swallow

Keep out of reach of children and pets.

5.1.3Check battery charge:

Service Interval: Monthly

Allowing batteries to stand for an extended period of time without recharging them will result in reduced performance and service life. To preserve optimum battery performance and life, recharge batteries in storage when the open circuit voltage drops to 12.4 volts.

Note: To prevent damage due to freezing, battery should be fully charged before putting away for winter storage.

a)Check the voltage of the battery with a digital voltmeter. Locate the voltage reading of the battery in the table below and charge the battery for the recommended time interval to bring the charge up to a full charge of 12.6 volts or greater.

IMPORTANT: Make sure the negative battery cables are disconnected and the battery charger used for charging the battery has an output of 16 volts and 7 amps or less to avoid damaging the battery (see chart below for recommended charger settings).

Voltage

Percent

Maximum

 

Charging Interval

Reading

Charge

Charger Settings

 

 

 

12.6 or greater

100%

16 volts/7 amps

No Charging Required

12.4 – 12.6

75

– 100%

16 volts/7 amps

30 Minutes

12.2 – 12.4

50

– 75%

16 volts/7 amps

1

Hour

12.0 – 12.2

25

– 50%

14.4 volts/4 amps

2

Hours

11.7 – 12.0

0 – 25%

14.4 volts/4 amps

3

Hours

11.7 or less

0%

14.4 volts/2 amps

6

Hours or More

- 27 -

Page 32
Image 32
Exmark Lazer HP manual Service Interval Monthly