5.1.4Check safety interlock system. Service Interval: Daily

a)For your safety, your Exmark mower is equipped with Operator Presence Controls (OPC). When either the PTO is engaged, or the transmission shift lever is not in neutral and both hands are removed from the handles, the mower engine MUST stop.

b)Check OPC circuits. Clear the area. Run engine at one-third throttle, then with drive levers and neutral lock/park brake latches in “park brake” position, Shift the transmission into gear and release OPC levers – engine

MUST stop.

Again, run engine at one-third throttle, move the transmission shifter lever to neutral, engage PTO and release OPC levers - engine MUST stop.

c)If machine does not pass any of these tests, DO NOT operate. Contact your authorized EXMARK SERVICE DEALER.

IMPORTANT: It is essential that all Operator Safety Mechanisms, be in place and in proper operating condition prior to mowing.

5.1.5Check for loose hardware. Service Interval: Daily

a)Stop engine and wait for all moving parts to stop. Remove ignition key or spark plug wire(s).

b)Visually inspect machine for any loose hardware or any other possible problem. Tighten hardware or correct the problem before operating.

5.1.6Check Brake and Wheel Drive Linkage Adjustment Service Interval: Daily

Refer to Section 3.11. Note any bent linkage or hardware, which may need servicing or replacing.

5.1.7Service pre-cleaner element and air cleaner. Service Interval: See Engine Owner's Manual

a)Stop engine and wait for all moving parts to stop. Remove key or spark plug wire(s).

b)See engine owners manual for cleaning instructions.

5.1.8Change engine oil.

Service Interval: See Engine Owner's Manual

NOTE: Change oil after first five (5) hours of operation. Follow engine manufacturer’s recommendations for future oil changes.