Extron electronic FOX T USW 103 manual Making Connections, Control Connectors, Power Connector

Models: FOX T USW 103

1 47
Download 47 pages 63.12 Kb
Page 12
Image 12

Control Connectors

FContact closure connector — Connect a contact closure device (such as a simple switch) to the 3.5 mm, 4-pole captive screw connector. The first three ports are used for selecting inputs 1 through 3 when momentarily shorted to the ground pin (see Wiring for Remote Contact Closure Communication on page 8).

GRS-232 connector — Connect a host device to the 3.5 mm, 3-pole captive screw connector for serial control of the switcher.

Power Connector

HPower connector — Connect an external power supply to the 3.5 mm, 2-pole captive screw connector (see Wiring the Power Supply on page 9).

Making Connections

Connecting HDMI Connectors

Use an Extron LockIt Lacing Bracket to secure an HDMI cable to each device as follows:

3

4

2

5 1

Figure 4. Installing the LockIt Lacing Bracket

1.Plug the HDMI cable into the panel connector.

2.Loosen the HDMI connection mounting screw from the panel enough to allow the LockIt lacing bracket to be placed over it. The screw does not have to be removed.

3.Place the LockIt lacing bracket on the screw and against the HDMI connector, then tighten the screw to secure the bracket.

ATTENTION: Do not overtighten the HDMI connector mounting screw. The shield to which it is fastened to is very thin and can easily be stripped.

4.Loosely place the included tie wrap around the HDMI connector and the LockIt lacing bracket as shown.

5.While holding the connector securely against the lacing bracket, use pliers or a similar tool to tighten the tie wrap, then remove any excess length.

FOX T USW 103 Universal Switcher • Installation

6