Extron electronic FOX T USW 103 manual Error responses, Symbol definitions

Models: FOX T USW 103

1 47
Download 47 pages 63.12 Kb
Page 19
Image 19
Error responses

Error responses

When the FOX T USW 103 receives an SIS command and determines that it is valid, it performs the command and sends the corresponding response to the host device. If the command is determined invalid or contains invalid parameters, the switcher or receiver returns an error response to the host. The error response codes are:

E01

= Invalid input number

E13

= Invalid parameter

E06

= Invalid switch attempt in this mode

E14

= Not valid for this configuration

E10

= Invalid command

E17

= Invalid command for signal type

E12

= Invalid port number

E22

= Busy

Using the command and response table for SIS commands

The Command and Response Tables begin on page 15. Lowercase letters are acceptable in the command field except where indicated. Figure 9 shows the hexadecimal equivalent of ASCII characters used in the command and response tables.

ASCII to Hex Conversion Table

Space Using the command and response table for SIS commands

Figure 9. ASCII to Hexadecimal Conversion

Symbol definitions

]

=

Carriage return and line feed

¦ or }

=

Carriage return with no line feed

= Space

E or W = Escape key

FOX T USW 103 Universal Switcher • Remote Control 13