Extron electronic MVX 88 Series manual Preliminary, Remote Operation, cont’d, RGB delay, Resets

Models: MVX 88 Series

1 84
Download 84 pages 63.57 Kb
Page 60
Image 60
RGB delay

PRELIMINARY

Remote Operation, cont’d

Command/response table for SIS commands (continued)

Command

ASCII command

Response

Additional

 

(host to switcher)

(switcher to host)

description

RGB delay

 

 

 

Set RGB delay

EX@*X1!D}

OutX@•DlyX1!]

 

Example:

E5*7D}

Out5•Dly07]

Set the RGB delay for a tie to

 

 

 

output 5 to 3.5 sec (7 x 0.5 sec.).

Read RGB delay

EX@D}

X1!]

 

Example:

E6D}

05]

Output 6 delay is 2.5 sec

 

 

 

(5 x 0.5 sec.).

Front panel lockout (Executive mode)

 

 

Lock front panel

1X

Exe1]

Enable executive mode.

Unlock front panel

0X

Exe0]

Disable executive mode.

View lock status

X

X#]

 

 

 

 

 

Resets

 

 

 

Reset global presets

EZG}

Zpg]

Clear all global presets.

Reset one global preset

EX(ZG}

ZpgX(]

Clear global preset X(.

Reset audio input levels

EZA}

Zpa]

Reset all audio input levels

 

 

 

such that the output is 0 dB.

Reset audio output levels

EZV}

Zpv]

Reset all audio output levels

 

 

 

to the professional level.

Reset all mutes

EZZ}

Zpz]

Unmute all video and audio

 

 

 

outputs.

Reset all RGB delay settings

EZD}

Zpd]

Reset all RGB delays to 0

 

 

 

seconds.

Reset whole switcher

EZXXX}

Zpx]

Clear all ties, global presets,

 

 

 

and mutes and reset all

 

 

 

audio gains to the factory

 

 

 

default.

Firmware upload

 

 

 

Upload firmware

Eupload

See “Loading firmware using SIS commands” on the next

 

 

page.

 

Information requests

 

 

 

Information request

I

VX$XX@•AX$XX@]

V (video) matrix size•

 

 

 

A (audio) matrix size

Example (MVX 84 VGA):

I

V8X4•A8X4]

8 RGB and audio inputs and

 

 

 

4 RGB and audio outputs.

Request part number

N

nn-nnn-nn]

See appendix A for part #s.

Example (MVX 88 VGAA):

N

60-638-21]

MVX 88 VGA A part # is

 

 

 

60-638-21.

Query controller firmware

Q

X1@]

 

version

 

 

 

Example:

Q

1.23]

The factory-installed

 

 

 

controller firmware version

 

 

 

is 1.23 (sample value only).

 

 

 

 

N X@= Output number

1

– (maximum number of outputs for your model)

X1!= RGB delay in ½ second increments (10 [5 seconds] maximum)
X#= Front panel lock

1

= on (locked)
X(= Global preset #

0

= off (unlocked)
00 - 16 (00 = current configuration)

X$= Input number

1

– (maximum number of inputs for your model)

X1@= Controller firmware version number to second decimal place

4-10 MVX 44 / 48 / 84 / 88 VGA Matrix Switchers • Remote Operation

Page 60
Image 60
Extron electronic MVX 88 Series Preliminary, Remote Operation, cont’d, Command/response table for SIS commands continued