Finisar AN-2030 specifications F i n i s a r, Reserved Optional Alarm and Warning Flag Bits

Models: AN-2030

1 35
Download 35 pages 39.34 Kb
Page 26
Image 26

 

AN-2030: Digital Diagnostic Monitoring Interface for Optical Transceivers

F i n i s a r

 

 

 

Table 3.18: Alarm and Warning Flag Bits (2-Wire Address A2h)

 

 

 

 

 

 

 

 

Reserved Optional Alarm and Warning Flag Bits

 

 

 

112

7

Temp High Alarm

Set when internal temperature exceeds high alarm level.

 

112

6

Temp Low Alarm

Set when internal temperature is below low alarm level.

 

112

5

Vcc High Alarm

Set when internal supply voltage exceeds high alarm level.

 

112

4

Vcc Low Alarm

Set when internal supply voltage is below low alarm level.

 

112

3

TX Bias High Alarm

Set when TX Bias current exceeds high alarm level.

 

112

2

TX Bias Low Alarm

Set when TX Bias current is below low alarm level.

 

112

1

TX Power High Alarm

Set when TX output power exceeds high alarm level.

 

112

0

TX Power Low Alarm

Set when TX output power is below low alarm level.

 

113

7

RX Power High Alarm

Set when Received Power exceeds high alarm level.

 

113

6

RX Power Low Alarm

Set when Received Power is below low alarm level.

 

113

5

Reserved Alarm

 

 

 

 

113

4

Reserved Alarm

 

 

 

 

113

3

Reserved Alarm

 

 

 

 

113

2

Reserved Alarm

 

 

 

 

113

1

Reserved Alarm

 

 

 

 

113

0

Reserved Alarm

 

 

 

 

114

All

Reserved

 

 

 

 

115

All

Reserved

 

 

 

 

116

7

Temp High Warning

Set when internal temperature exceeds high warning level.

 

116

6

Temp Low Warning

Set when internal temperature is below low warning level.

 

116

5

Vcc High Warning

Set when internal supply voltage exceeds high warning level.

 

116

4

Vcc Low Warning

Set when internal supply voltage is below low warning level.

 

116

3

TX Bias High Warning

Set when TX Bias current exceeds high warning level.

 

116

2

TX Bias Low Warning

Set when TX Bias current is below low warning level.

 

116

1

TX Power High Warning

Set when TX output power exceeds high warning level.

 

116

0

TX Power Low Warning

Set when TX output power is below low warning level.

 

117

7

RX Power High Warning

Set when Received Power exceeds high warning level.

 

117

6

RX Power Low Warning

Set when Received Power is below low warning level.

 

117

5

Reserved Warning

 

 

 

 

117

4

Reserved Warning

 

 

 

 

117

3

Reserved Warning

 

 

 

 

117

2

Reserved Warning

 

 

 

 

117

1

Reserved Warning

 

 

 

 

117

0

Reserved Warning

 

 

 

 

118

All

Reserved

 

 

 

 

119

All

Reserved

 

 

 

9/26/02 Revision D

Page 26

Page 26
Image 26
Finisar AN-2030 specifications F i n i s a r, Reserved Optional Alarm and Warning Flag Bits