| F i n i s a r | ||||
1 |
|
| Table 3.1 Serial ID: Data Fields – Address A0 |
| |
|
|
|
|
|
|
| Data | Size | Name of |
|
|
| (Bytes) | Description of Field |
| ||
| Address | Field |
| ||
|
|
|
| BASE ID FIELDS |
|
| 0 | 1 | Identifier | Type of serial transceiver (see table 3.2) |
|
| 1 | 1 | Ext. Identifier | Extended identifier of type of serial transceiver |
|
| 2 | 1 | Connector | Code for connector type (see table 3.3) |
|
| 8 | Transceiver | Code for electronic compatibility or optical compatibility | ||
|
|
|
| (see table 3.4) |
|
| 11 | 1 | Encoding | Code for serial encoding algorithm (see table 3.5) |
|
| 12 | 1 | BR, Nominal | Nominal bit rate, units of 100 MBits/sec. |
|
| 13 | 1 | Reserved |
|
|
| 14 | 1 | Length(9µm) - | Link length supported for 9/125 µm fiber, units of km | |
|
|
| km |
|
|
| 15 | 1 | Length (9µm) | Link length supported for 9/125 µm fiber, units of 100 m | |
| 16 | 1 | Length (50µm) | Link length supported for 50/125 µm fiber, units of 10 m | |
| 17 | 1 | Length (62.5µm) | Link length supported for 62.5/125 µm fiber, units of 10 m | |
| 18 | 1 | Length (Copper) | Link length supported for copper, units of meters |
|
| 19 | 1 | Reserved |
|
|
| 16 | Vendor name | SFP vendor name (ASCII) |
| |
| 36 | 1 | Reserved | DWDM channel spacing - DWDM modules only |
|
| 3 | Vendor OUI | SFP vendor IEEE company ID |
| |
| 16 | Vendor PN | Part number provided by SFP vendor (ASCII) |
| |
| 4 | Vendor rev | Revision level for part number provided by vendor (ASCII) | ||
| 2 | Wavelength | Laser wavelength |
| |
| 62 | 1 | Reserved | DWDM wavelength fraction - DWDM modules only | |
| 63 | 1 | CC_BASE | Check code for Base ID Fields (addresses 0 to 62) | |
|
|
|
| EXTENDED ID FIELDS |
|
| 2 | Options | Indicates which optional transceiver signals are implemented | ||
|
|
|
| (see table 3.6) |
|
| 66 | 1 | BR, max | Upper bit rate margin, units of % |
|
| 67 | 1 | BR, min | Lower bit rate margin, units of % |
|
| 16 | Vendor SN | Serial number provided by vendor (ASCII) |
| |
| 8 | Date code | Vendor’s manufacturing date code (see table 3.7) |
| |
| 92 | 1 | Diagnostic | Indicates which type of diagnostic monitoring is implemented (if | |
|
|
| Monitoring Type | any) in the transceiver (see Table 3.8) |
|
| 93 | 1 | Enhanced | Indicates which optional enhanced features are implemented (if any) | |
|
|
| Options | in the transceiver (see Table 3.9) |
|
| 94 | 1 | Indicates which revision of | ||
|
|
| Compliance | (see table 3.11) |
|
| 95 | 1 | CC_EXT | Check code for the Extended ID Fields (addresses 64 to 94) | |
|
|
|
| VENDOR SPECIFIC ID FIELDS |
|
| 32 | Vendor Specific | Vendor Specific EEPROM |
| |
| 128 | Reserved | Reserved for future use. |
|
9/26/02 Revision D | Page 4 |