AN-2030: Digital Diagnostic Monitoring Interface for Optical Transceivers

1

F i n i s a r

2

Table 3.10: I/O Timing for Soft Control & Status Functions

 

 

 

 

 

 

 

 

 

Parameter

Symbol

Min

Max

Units

 

Conditions

 

 

 

 

 

 

 

 

 

TX_DISABLE assert time

t_off

 

ms

 

Time from TX_DISABLE bit set1

 

 

100

 

 

 

 

 

 

 

 

until optical output falls below

 

 

 

 

 

 

 

10% of nominal

 

TX_DISABLE deassert time

t_on

 

100

ms

 

Time from TX_DISABLE bit

 

 

 

 

 

 

 

cleared1 until optical output rises

 

 

 

 

 

 

 

above 90% of nominal

 

Time to initialize, including

t_init

 

300

ms

 

From power on or negation of

 

reset of TX_FAULT

 

 

 

 

 

TX_FAULT using TX_DISABLE;

 

 

 

 

 

 

 

serial communication possible

 

TX_FAULT assert time

t_fault

 

100

ms

 

Time from fault to TX_FAULT bit

 

 

 

 

 

 

 

set.

 

LOS assert time

t_loss_on

 

100

ms

 

Time from LOS state to RX_LOS

 

 

 

 

 

 

 

bit set

 

LOS deassert time

t_loss_off

 

100

ms

 

Time from non-LOS state to

 

 

 

 

 

 

 

RX_LOS bit cleared

 

Rate select change time

T_rate_sel

 

100

ms

 

Time from change of state of Rate

 

 

 

 

 

 

 

Select bit1 until receiver

 

 

 

 

 

 

 

bandwidth is in conformance with

 

 

 

 

 

 

 

appropriate specification

 

Serial ID clock rate

f_serial_cl

 

100

kHz

 

n/a

 

 

ock

 

 

 

 

 

 

Analog parameter data ready

t_data

 

1000

ms

 

From power on to data ready, bit

 

1 measured from falling clock edge after stop

 

 

 

 

0 of byte 110 set

 

bit of

write transaction.

 

 

3

 

 

 

 

 

 

 

4SFF-8472 Compliance

5 Byte 94 contains an unsigned integer that indicates which feature set(s) are

6implemented in the transceiver.

7

 

 

 

 

8

 

Table 3.11: SFF-8472 Compliance

 

 

 

 

 

 

Data Address

 

Value

Interpretation

 

 

 

 

 

 

 

 

 

 

94

 

0

Digital diagnostic functionality not included or

 

 

 

 

undefined.

 

 

 

 

 

 

94

 

1

Includes functionality described in Rev 9.3

 

 

 

 

SFF-8472.

 

 

 

 

 

 

94

 

2

TBD

 

 

 

 

 

 

94

 

3

TBD

9

 

 

 

 

 

 

 

 

10CC_EXT

11The check code is a one byte code that can be used to verify that the first 32 bytes of

12extended serial information in the SFP is valid. The check code shall be the low order 8

13bits of the sum of the contents of all the bytes from byte 64 to byte 94, inclusive.

9/26/02 Revision D

Page 16

Page 16
Image 16
Finisar AN-2030 specifications 10 I/O Timing for Soft Control & Status Functions, SFF-8472 Compliance