Finisar AN-2030 specifications F i n i s a r, 1Calibration Constants, Wire Address A2h

Models: AN-2030

1 35
Download 35 pages 39.34 Kb
Page 21
Image 21
1Calibration Constants

AN-2030: Digital Diagnostic Monitoring Interface for Optical Transceivers

F i n i s a r

1Calibration Constants

2

 

TABLE 3.15: Calibration constants for External Calibration Option

3

 

4

 

 

 

(2 Wire Address A2h)

5

 

 

 

 

 

Address

# Bytes

Name

Description

 

 

 

 

 

 

56-59

4

Rx_PWR(4)

Single precision floating point calibration data - Rx optical power. Bit

 

 

 

 

7 of byte 56 is MSB. Bit 0 of byte 59 is LSB. Rx_PWR(4) is set to

 

 

 

 

zero for “internally calibrated” devices.

 

 

 

 

 

 

60-63

4

Rx_PWR(3)

Single precision floating point calibration data - Rx optical power.

 

 

 

 

Bit 7 of byte 60 is MSB. Bit 0 of byte 63 is LSB. Rx_PWR(3) is set to

 

 

 

 

zero for “internally calibrated” devices.

 

64-67

4

Rx_PWR(2)

Single precision floating point calibration data, Rx optical power.

 

 

 

 

Bit 7 of byte 64 is MSB, bit 0 of byte 67 is LSB. Rx_PWR(2) is set to

 

 

 

 

zero for “internally calibrated” devices.

 

68-71

4

Rx_PWR(1)

Single precision floating point calibration data, Rx optical power. Bit 7

 

 

 

 

of byte 68 is MSB, bit 0 of byte 71 is LSB. Rx_PWR(1) is set to 1 for

 

 

 

 

“internally calibrated” devices.

 

72-75

4

Rx_PWR(0)

Single precision floating point calibration data, Rx optical power. Bit 7

 

 

 

 

of byte 72 is MSB, bit 0 of byte 75 is LSB. Rx_PWR(0) is set to zero

 

 

 

 

for “internally calibrated” devices.

 

 

 

 

 

 

76-77

2

Tx_I(Slope)

Fixed decimal (unsigned) calibration data, laser bias current. Bit 7 of

 

 

 

 

byte 76 is MSB, bit 0 of byte 77 is LSB. Tx_I(Slope) is set to 1 for

 

 

 

 

“internally calibrated” devices.

 

78-79

2

Tx_I(Offset)

Fixed decimal (signed two’s complement) calibration data, laser bias

 

 

 

 

current. Bit 7 of byte 78 is MSB, bit 0 of byte 79 is LSB. Tx_I(Offset)

 

 

 

 

is set to zero for “internally calibrated” devices.

 

80-81

2

Tx_PWR(Slope)

Fixed decimal (unsigned) calibration data, transmitter coupled output

 

 

 

 

power. Bit 7 of byte 80 is MSB, bit 0 of byte 81 is LSB.

 

 

 

 

Tx_PWR(Slope) is set to 1 for “internally calibrated” devices.

 

 

 

 

 

 

82-83

2

Tx_PWR(Offset)

Fixed decimal (signed two’s complement) calibration data,

 

 

 

 

transmitter coupled output power. Bit 7 of byte 82 is MSB, bit 0 of

 

 

 

 

byte 83 is LSB. Tx_PWR(Offset) is set to zero for “internally

 

 

 

 

calibrated” devices.

 

84-85

2

T (Slope)

Fixed decimal (unsigned) calibration data, internal module

 

 

 

 

temperature. Bit 7 of byte 84 is MSB, bit 0 of byte 85 is LSB.

 

 

 

 

T(Slope) is set to 1 for “internally calibrated” devices.

 

86-87

2

T (Offset)

Fixed decimal (signed two’s complement) calibration data, internal

 

 

 

 

module temperature. Bit 7 of byte 86 is MSB, bit 0 of byte 87 is LSB.

 

 

 

 

T(Offset) is set to zero for “internally calibrated” devices.

 

 

 

 

 

 

88-89

2

V (Slope)

Fixed decimal (unsigned) calibration data, internal module supply

 

 

 

 

voltage. Bit 7 of byte 88 is MSB, bit 0 of byte 89 is LSB. V(Slope) is

 

 

 

 

set to 1 for “internally calibrated” devices.

 

90-91

2

V (Offset)

Fixed decimal (signed two’s complement) calibration data, internal

 

 

 

 

module supply voltage. Bit 7 of byte 90 is MSB. Bit 0 of byte 91 is

 

 

 

 

LSB. V(Offset) is set to zero for “internally calibrated” devices.

 

92-4

3

Reserved

Reserved

6

95

1

Checksum

Byte 95 contains the low order 8 bits of the sum of bytes 0 – 94.

 

 

 

 

 

 

 

 

7

 

 

 

 

8

 

 

 

 

9/26/02 Revision D

Page 21