Image 77
Connecting to the 10/100 and 10/100/1000 Ports

Chapter 2 Switch Installation

Connecting to the 10/100 and 10/100/1000 Ports

Step 6 Use two Phillips-head screws to attach the XENPAK module slot cover to the switch front panel, as shown in Figure 2-54.

Figure 2-54 Replacing the XENPAK Module Slot Cover

1

Catalyst

 

3750

series

 

1

104765

2

1

Phillips-head screw

2

Module slot cover

Connecting to the 10/100 and 10/100/1000 Ports

The switch 10/100 and 10/100/1000 ports configure themselves to operate at the speed of attached devices. If the attached ports do not support autonegotiation, you can explicitly set the speed and duplex parameters. Connecting devices that do not autonegotiate or that have their speed and duplex parameters manually set can reduce performance or result in no linkage.

To maximize performance, choose one of these methods for configuring the Ethernet ports:

Let the ports autonegotiate both speed and duplex.

Set the port speed and duplex parameters on both ends of the connection.

Warning Voltages that present a shock hazard may exist on Power over Ethernet (PoE) circuits if interconnections are made using uninsulated exposed metal contacts, conductors, or terminals. Avoid using such interconnection methods, unless the exposed metal parts are located within a restricted access location and users and service people who are authorized within the restricted access location are made aware of the hazard. A restricted access area can be accessed only through the use of a special tool, lock and key or other means of security. Statement 1072

You can configure the 10/100 and 10/100/1000 ports on the Catalyst 3750-24PS, 3750G-24PS, 3750-48PS, 3750G-48PS, 3750G-24WS-S25, and the 3750G-24WS-S50 switches to either automatically provide PoE when a Cisco IP Phone, Cisco Aironet Access Point, or end device compliant with IEEE 802.3af is connected. Alternatively, you can configure them to never provide PoE, even if an IP phone or an access point is connected. The default setting is Auto. To prevent ESD damage, follow your normal board and component handling procedures.

Use the guidelines in Table 2-1to select the correct cable for connecting the switch 10/100 and 10/100/1000 ports to other devices. See the “Cable and Adapter Specifications” section on page B-5for cable-pinout descriptions.

Catalyst 3750 Switch Hardware Installation Guide

 

OL-6336-07

2-39

 

 

 