(MHz/km)1

Appendix B Connector and Cable Specifications

Cable and Adapter Specifications

Table B-3

Fiber-Optic SFP Module Port Cabling Specifications (continued)

 

 

 

 

 

 

 

 

 

 

Wavelength

 

Core Size/Cladding

Modal Bandwidth

 

SFP Module

 

(nanometers)

Fiber Type

Size (micron)

(MHz/km)1

Cable Distance

1000BASE-BX10-D

1490 TX

SMF

G.6522

32,810 feet (10 km)

(GLC-BX-D)

 

1310 RX

 

 

 

 

 

 

 

 

 

 

1000BASE-BX10-U

1310 TX

SMF

G.6522

32,810 feet (10 km)

(GLC-BX-U)

 

1490 RX

 

 

 

 

 

 

 

 

 

 

 

1000BASE-SX

 

850

MMF

62.5/125

160

722 feet (220 m)

(GLC-SX-MM)

 

 

 

62.5/125

200

902 feet (275 m)

 

 

 

 

50/125

400

1640 feet (500 m)

 

 

 

 

50/125

500

1804 feet (550 m)

 

 

 

 

 

 

1000BASE-LX/LH

1310

MMF3

62.5/125

500

1804 feet (550 m)

(GLC-LH-SM)

 

 

 

50/125

400

1804 feet (550 m)

 

 

 

 

50/125

500

1804 feet (550 m)

 

 

 

SMF

G.6522

32,810 feet (10 km)

1000BASE-ZX

 

1550

SMF

G.6522

43.4 to 62 miles

(GLC-ZX-SM

 

 

 

 

 

(70 to 100 km)4

CWDM

 

1470, 1490,

SMF

G.6522

62 miles (100 km)

 

 

1510, 1530,

 

 

 

 

 

 

1550, 1570,

 

 

 

 

 

 

1590, 1610

 

 

 

 

 

 

 

 

 

 

 

1.Modal bandwidth applies only to multimode fiber.

2.A mode-field diameter/cladding diameter = 9 micrometers/125 micrometers

3.A mode-conditioning patch cord is required. Using an ordinary patch cord with MMF, 1000BASE-LX/LH SFP modules, and a short link distance can cause transceiver saturation, resulting in an elevated bit error rate (BER). When using the LX/LH SFP module with 62.5-micron diameter MMF, you must also install a mode-conditioning patch cord between the SFP module and the MMF cable on both the sending and receiving ends of the link. The mode-conditioning patch cord is required for link distances greater than 984 feet (300 m).

4.1000BASE-ZX SFP modules can send data up to 62 miles (100 km) by using dispersion-shifted SMF or low-attenuation SMF; the distance depends on the fiber quality, the number of splices, and the connectors.

Two Twisted-Pair Cable Pinouts

Figure B-7and Figure B-8show the schematics of two twisted-pair cables for 10/100 ports.

Figure B-7

Switch

3TD+

6 TD–

1RD+

2 RD–

Two Twisted-Pair Straight-Through Cable Schematic

Router or PC

Two Twisted-Pair Cable Pinouts 3 RD+ Manual background 6 RD–

1 TD+

H5578

2 TD–

 

Catalyst 3750 Switch Hardware Installation Guide

 

B-6

OL-6336-07

 

 

 

Page 116
Image 116
Cisco Systems WSC3750X24TS Two Twisted-Pair Cable Pinouts, Wavelength, SFP Module, nanometers, Fiber Type, Size micron