Appendix C Connecting to DC Power

Connecting to DC Power

Step 3 Identify the positive and negative feed positions for the terminal block connection. The wiring sequence is positive to positive and negative to negative for both the A and the B feed wires. The switch rear panel identifies the positive and negative positions for both the A and B feed wires, as shown in Figure C-5.

Figure C-5 Positive and Negative Positions on the Switch Rear Panel

STACK 1

STACK 2

CONSOLE

 

 

 

36 -

3.0

72V

-

 

1.5A

 

B –

 

+

 

A –

 

+

36

- 72V

3.0 -

 

1.5A

 

B –

 

+

 

A –

 

+

132976

Step 4 Using a 18-gauge wire-stripping tool, strip each of the four wires coming from the DC-input power source to 0.27 inch (6.6 mm) ± 0.02 inch (0.5 mm), as shown in Figure C-6. Do not strip more than 0.29 inch (7.4 mm) of insulation from the wire. Stripping more than the recommended amount of wire can leave exposed wire from the terminal block plug after installation.

Figure C-6 Stripping the DC-Input Power Source Wire

0.25 inch (6.3 mm) ± 0.02 inch (0.5 mm)

86460

Catalyst 3750 Switch Hardware Installation Guide

 

OL-6336-07

C-5

 

Page 125
Image 125
Cisco Systems WSC3750X24TS specifications Figure C-6 Stripping the DC-Input Power Source Wire