Appendix B Connector and Cable Specifications

Connector Specifications

10/100 and 10/100 /1000 Ports

The 10/100 and 10/100/1000 Ethernet ports on Catalyst 3750 switches use standard RJ-45 connectors and Ethernet pinouts with internal crossovers. Figure B-2and Figure B-1show the pinouts.

Figure B-1 10/100 Port Pinouts

Pin Label

1RD+

2RD-

3TD+

4NC

5NC

6TD-

7NC

8NC

1 2 3 4 5 6 7 8

H5318

Figure B-2 10/100/1000 Port Pinouts

Pin Label

1TP0+

2TP0-

3TP1+

4TP2+

5TP2-

6TP1-

7TP3+

8TP3-

1 2 3 4 5 6 7 8

60915

100BASE-FX Ports

The 100BASE-FX ports use MT-RJ connectors, as shown in Figure B-3. The 100BASE-FX ports use 50/125- or 62.5/125-micron multimode fiber-optic cabling.

You can connect a 100BASE-FX port to an SC or ST port on a target device by using one of the MT-RJ fiber-optic patch cables listed in Table B-1. Use the Cisco part numbers in Table B-1to order the patch cables that you need.

Catalyst 3750 Switch Hardware Installation Guide

 

B-2

OL-6336-07

 

 

 

Page 112
Image 112
Cisco Systems WSC3750X24TS specifications 10/100 and 10/100 /1000 Ports, Figure B-1 10/100 Port Pinouts