Chapter 2 Switch Installation

Planning the Stack

Figure 2-1 Example of a Stack with Full Bandwidth Connections

A

B

C

86821

Figure 2-2shows an example of a stack of Catalyst 3750 switches with incomplete StackWise cabling connections. This stack provides only half bandwidth and does not have redundant connections.

Figure 2-2 Example of a Stack with Half Bandwidth Connections

A

B

86823

Figure 2-3and Figure 2-4show examples of stacks of Catalyst 3750 switches with failover conditions. In Figure 2-3, the StackWise cable is bad in link B; therefore, this stack provides only half bandwidth and does not have redundant connections. In Figure 2-4, link B is bad; therefore, this stack partitions into two stacks, and switch 1 and switch 3 are stack masters.

Figure 2-3 Example of a Stack with a Failover Condition

A

B

C

86822

Figure 2-4 Example of a Partitioned Stack with a Failover Condition

A

B

86824

 

Catalyst 3750 Switch Hardware Installation Guide

 

OL-6336-07

2-9

 

 

 

Page 47
Image 47
Cisco Systems WSC3750X24TS specifications Example of a Stack with Full Bandwidth Connections