Cisco Systems WSC3750X24TS specifications

Models: WSC3750X24TS

1 144
Download 144 pages 14.95 Kb
Page 128
Image 128
Manual background

Appendix C Connecting to DC Power

Connecting to DC Power

Step 8 Insert the terminal block plug in the terminal block header on the switch rear panel, as shown in Figure C-10.

Caution Secure the wires coming in from the terminal block so that they cannot be disturbed by casual contact. For example, use tie wraps to secure the wires to the rack.

Figure C-10 Inserting the Terminal Block in the Block Header

STACK 1 Manual backgroundManual background STACK 2

1Tie wrap

CONSOLE

2

36

- 72V

3.0 -

 

1.5A

 

B –

 

+

2

1

Terminal block

Manual background132636

Step 9 Remove the tape from the circuit-breaker switch handle, and move the circuit-breaker handle to the on position.

Caution To comply with the intrabuilding lightning surge requirements, intrabuilding wiring must be shielded, and the shield for the wiring must be grounded at both ends.

Caution The Catalyst 3750G-12S-SD switch is suitable only for intrabuilding or nonexposed wiring connections.

Catalyst 3750 Switch Hardware Installation Guide

 

C-8

OL-6336-07

 

 

 

Page 128
Image 128
Cisco Systems WSC3750X24TS specifications