AN-2030: Digital Diagnostic Monitoring Interface for Optical Transceivers

F i n i s a r

15) Measured received optical power. Received power, RX_PWR, is given in µW by

2the following equation:

3Rx_PWR (µW) = Rx_PWR(4) * Rx_PWRAD4 (16 bit unsigned integer) +

4Rx_PWR(3)*Rx_PWRAD3(16 bit unsigned integer) + Rx_PWR(2)*Rx_PWRAD2(16 bit

5unsigned integer) + Rx_PWR(1) *Rx_PWRAD (16 bit unsigned integer) + Rx_PWR(0)

6The result is in units of 0.1µW yielding a total range of 0 – 6.5mW. See Table 3.15 for

7locations of Rx_PWR(4-0). Absolute accuracy is dependent upon the exact optical

8wavelength. For the specified wavelength, accuracy shall be better than ±3dB over

9specified temperature and voltage. See module specification sheet for range over

10which accuracy requirement is met.

11

12Alarm and Warning Thresholds

13Each A/D quantity has a corresponding high alarm, low alarm, high warning and low

14warning threshold. These factory preset values allow the user to determine when a

15 particular value is outside of “normal” limits. These values vary with different

16technologies and implementations.

17

 

Table 3.14: Alarm and Warning Thresholds (2-Wire Address A2h)

18

 

 

 

 

 

 

 

Address

# Bytes

Name

Description

 

 

 

 

 

 

00-01

2

Temp High Alarm

MSB at low address

 

02-03

2

Temp Low Alarm

MSB at low address

 

 

 

04-05

2

Temp High Warning

MSB at low address

 

 

 

06-07

2

Temp Low Warning

MSB at low address

 

 

 

08-09

2

Voltage High Alarm

MSB at low address

 

 

 

10-11

2

Voltage Low Alarm

MSB at low address

 

 

 

12-13

2

Voltage High Warning

MSB at low address

 

 

 

14-15

2

Voltage Low Warning

MSB at low address

 

 

 

16-17

2

Bias High Alarm

MSB at low address

 

 

 

18-19

2

Bias Low Alarm

MSB at low address

 

 

 

20-21

2

Bias High Warning

MSB at low address

 

 

 

22-23

2

Bias Low Warning

MSB at low address

 

 

 

24-25

2

TX Power High Alarm

MSB at low address

 

 

 

26-27

2

TX Power Low Alarm

MSB at low address

 

 

 

28-29

2

TX Power High Warning

MSB at low address

 

 

 

30-31

2

TX Power Low Warning

MSB at low address

 

 

 

32-33

2

RX Power High Alarm

MSB at low address

 

 

 

34-35

2

RX Power Low Alarm

MSB at low address

 

 

 

36-37

2

RX Power High Warning

MSB at low address

 

 

 

38-39

2

RX Power Low Warning

MSB at low address

 

 

19

40-55

16

Reserved

Reserved for future monitored quantities

 

 

 

 

20

 

 

 

 

21

9/26/02 Revision D

 

Page 20

 

 

Page 20
Image 20
Finisar AN-2030 specifications Alarm and Warning Thresholds 2-Wire Address A2h