CM-3300 WIRING DETAIL

CONNECTOR 1

Pin 1 Brown- Siren 12-volt (+) positive output. This wire will provide a 30 or 60 second

(+) positive output for the external siren. (Note: Factory default is 30 seconds.)

Pin 2 Green/White- Parking light (+) positive output. Connect this wire to the (+) positive parking light wire generally at the parking light switch or behind the fuse box. The proper wire will test 12-volts (+) positive when the parking light switch is in the on position.

Pin 1 Red- Constant 12-volt (+) positive power input for the control module. This wire must be connected to a constant 12-volt (+) positive source. The proper wire will test 12-volt (+) positive with the key in the off position, while key is in the on position and during crank.

Pin 4 Black- Ground (-) negative input. This wire will connect to chassis ground.

CONNECTOR 2

Pin 1 Green/White- Parking light 250mA (-) negative output. This is an optional output that will provide a (-) negative output with parking light flash.

Pin 2 White- Horn honk 250mA (-) negative output. This is an optional output that will provide a 30 or 60 second (-) negative pulse when the alarm is triggered or during panic.

Pin 3 Yellow- Aux 1- 250mA (-) negative output. This is an optional output that will provide a pulse, latch or a timed pulse output. (Note: Options programmer is required to program a timed pulse output.)

Pin 4 Yellow/White- Aux 2- 250mA (-) negative output. This is an optional output that will provide a pulse, latch or a timed pulse output. (Note: Options programmer is required to program a timed pulse output.)

Pin 5 Violet- 250mA (-) negative output when armed. This wire will provide a (-) negative output when system is locked and armed. (Note: This wire can also be used to trigger after-market L.E.D. kits and other after-market accessories. Output must be diode isolated when used to trigger after-market accessories.)