Pin 4 Violet/Black- Trunk-pin (-) negative input. This is an optional input that will monitor when the vehicles trunk is opened. (Note: This wire will also trigger the alarm when the system is armed.)

Pin 5 Red/White- Door trigger (-) negative input. This wire monitors (-) negative trigger door-pins. The proper wire will provide a (-) negative trigger only when the doors are opened. (Note: This wire is required for manual transmission remote starts.)

Pin 6 Red- Door trigger (+) positive input. This wire monitors (+) positive trigger door- pins. The proper wire will provide a (+) positive trigger only when the doors are opened. (Note: This wire is required for manual transmission remote starts.)

Pin 7 Brown/Black- Glow plug (-) negative input. This wire will delay the starter output to allow the glow plugs to warm up on diesel engine vehicles. The proper wire will only provide a (-) negative trigger while the “Wait to Start” light is on.

Pin 8 Brown/White- Glow plug (+) positive input. This wire will delay the starter output to allow the glow plugs to warm up on diesel engine vehicles. The proper wire will only provide a (+) positive trigger while the “Wait to Start” light is on.

Pin 9 Yellow/Black- Engine sensing input. A tach input or alternator input is required for the system to sense when the vehicle is running. (Note: Option selected by dipswitch #1. On=Tach sensing. Off=Alternator sensing.)

CONNECTOR 4

Pin 1 Not used

Pin 2 Violet/White- Trunk release 250mA (-) negative output. This wire will provide a (-) negative trigger pulse. (Note: Positive trigger trunk release will require a relay. System will unlock doors and disarm alarm prior to trunk release.)

Pin 3 Orange/Black- 2nd Unlock 250mA (-) negative output. This wire is an optional output that will provide a (-) negative pulse output for driver’s priority door lock. (Note: This feature will require additional relays and programming.)

Pin 4 Blue- Unlock 250mA (-) negative output. This wire will provide a (-) negative pulse output during unlock and disarm. (Note: Positive and reverse polarity will require additional relays.)

Pin 5 Blue/Black- Lock 250mA (-) negative output. This wire will provide a (-) negative pulse output during lock and arm. (Note: Positive and reverse polarity will require additional relays.

- 22 -

Page 22
Image 22
Firstech, LLC CM1000A, CM3 SERIES, CM4200 manual Pin 1 Not used