will stay latched until the auxiliary output is activated again. If the Option Programmer is used, you can program this output for a timed latched output of 3 to 99 seconds.

2-8Siren Output Duration

With this option on the default setting, if the alarm is triggered, the siren will sound for 30 seconds. On the optional setting, the siren will sound for 60 seconds.

2-9Channel Expander Mode

This option requires the installation of the optional Channel Expander module. If you need more than the 2 supplied auxiliary outputs, you can install the Channel Expander for 5 additional outputs. With this option turned on, the Aux 2 wire from the system becomes non functional and the Aux 1 wire becomes the data wire that communicates with the Channel Expander. Please see the Channel Expander instruction manual for more details.

2-10Passive Arming With Channel Expander Mode Enabled

The ability to activate/deactivate Passive Arming through the remote is lost once Channel Expander mode is activated. If the Channel Expander is being used, set this option to the optional setting to activate Passive Arming. Leave it on the default setting to prevent Passive Arming.

Additional Programming

Some additional features have been added to the CompuStar systems that are not programmed through the option menus. Details on how to program these options are listed here