Pin 6 Green –Ignition input. This wire must be connected to the vehicles ignition to trigger remote programming. The proper wire will test 0-volts with the key in the off position, 12-volts (+) positive while the key is in the on position and 12-volts

(+) positive during crank.

Pin 7 Violet- Dome light 250mA (-) negative output. This is an optional output that will provide a 30 second (-) negative output after system is unlocked for dome-light supervision.

Pin 8 Orange- Factory alarm re-arm 250mA (-) negative output. This is an optional output that will provide a (-) negative pulse output during lock, after crank and after ignition shut down.

Pin 9 Orange/White- Factory alarm disarm 250mA (-) negative output. This is an optional output that will provide a (-) negative pulse output during unlock and before ignition is turned on.

CONNECTOR 3

Pin 1 Gray/Black- Hood-pin (-) negative input. This is an optional input that will monitor when the vehicles hood is opened.. (Note: This wire will also trigger alarm when system is armed.)

.

Pin 2 Violet/Black- Trunk-pin (-) negative input. This is an optional input that will monitor when the vehicles trunk is opened. (Note: This wire will also trigger alarm when system is armed.)

Pin 3 Red/White- Door trigger (-) negative input. This wire monitors (-) negative trigger door-pins. The proper wire will provide a (-) negative trigger only when the doors are opened.

Pin 4 Red- Door trigger (+) positive input. This wire monitors (+) positive trigger door- pins. The proper wire will provide a (+) positive trigger only when the doors are opened.

Pin 5 Black /White- Optional sensor 2nd stage (-) negative input. (Instant trigger) Pin 6 Gray/White- Optional sensor 1st stage (-) negative input. (Warn away)