CM4200

Manual Transmission Auto-Lock

With this option on the default setting, the doors will lock right after reservation mode is set. On the optional setting, the doors will have to be locked with the remote after reservation mode has been set.

1-12CM4200:

Delayed Door Trigger for Locking

With this option turned on, the system will ignore the door trigger for 90 seconds after the lock command has been issued. This will prevent the “door open” indication on 2-way remotes. If the door is still seen as open after 90 seconds, the remote will be paged to indicate that the door is still open.

1-13CM4200:

Factory Style Alarm

With this option turned on, the 4200 starter only system will function as a factory style alarm by monitoring the door trigger and sounding the horn and flashing the parking lights if the door is opened after the doors have been locked.

1-14CM4200:

Double Pulse Start Input

With this option turned on, the ground trigger start input of the temp sensor will require 2 pulses to initiate the start sequence. This will allow you to install the system as a slave start unit by tying the start input to the lock wire in the vehicle. Make sure it is a ground pulse, or flip the polarity with a relay.

2-1Cold Start with Temperature Sensor

To use this option, an optional temperature sensor must be installed. With this option turned on, the system will check the status of the temperature sensor every

1.5to 3.0 hours, depending on the setting of option 2-2. If the temperature of the sensor is below the specified start temperature, the system will remote start.

2-2Timer Start, or Minimum Interval Between Cold Starts.

This option regulates the start intervals in Cold Start and Timer Start modes. On the default setting, if Timer mode is activated, the system will remote start every 3 hours. If the optional temperature sensor is installed, and option 2-2 is turned on, the system will check the status of the temperature sensor every 3 hours. On the optional setting, if Timer mode is activated, the system will remote start every 1.5 hours. If the optional temperature sensor is installed, and option 2-2 is turned on, the system will check the status of the temperature sensor every 1.5 hours.

2-3Lock Behavior During Passive Arming

With this option on the default setting, the doors will lock once Passive Arming mode has armed the alarm. With this option on the optional setting, the doors will remain unlocked even if the system passively arms.