CONNECTOR 4

Pin 1 Not used

Pin 2 Violet/White- Trunk release 250mA (-) negative output. This wire will provide a (- ) negative trigger pulse. (Note: Positive trigger trunk release will require a relay. System will unlock doors and disarm alarm prior to trunk release.)

Pin 3 Orange/Black- 2nd Unlock 250mA (-) negative output. This wire is an optional output that will provide a (-) negative pulse output for driver’s priority door lock. (Note: This feature will require additional relays and programming.)

Pin 4 Blue- Unlock 250mA (-) negative output. This wire will provide a (-) negative pulse output during unlock and disarm. (Note: Positive and reverse polarity will require additional relays.)

Pin 5 Blue/Black- Lock 250mA (-) negative output. This wire will provide a (-) negative pulse output during lock and arm. (Note: Positive and reverse polarity will require additional relays.

Pin 6 Not used.

CONNECTOR 5

(Pre-wired L.E.D.)

Pin 1 Black-L.E.D. - (-) negative output.

Pin 2 Black/White - 3-volt L.E.D. (+) positive output.

CONNECTOR 6

(Pre-wired Shock Sensor)

Pin 1 Black-Shock sensor (-) negative ground input.

Pin 2 White-Shock sensor 2nd stage (-) negative input. (Instant trigger) Pin 3 Red-Shock sensor 12-volt (+) positive input.

Pin 4 Yellow-Shock sensor 1st stage (-) negative input. (Warn away)

- 30 -