INSTALLATION

(Model VDC-D1184VA)

(Model VDC-D2184VA)

73mm

Note: When setting up this camera, make sure that it is installed securely. If it is not installed correctly, it may fall down. In addition, do not touch the camera in places except where settings and adjustments are necessary.

Coaxial cable type and maximum length

(H) (G)

(D)

(C)

(E)

(F)

(A)

(K)

(B)

Cable type RG-59U (3C-2V), 250 m maximum.

(H)

 

 

 

(G)

Cable type RG-6U (5C-2V), 500 m maximum.

 

 

 

Cable type RG-11U (7C-2V), 600 m maximum.

 

 

 

 

(D)

Installing the Model VDC-D1184VA

(C) 1

Use the supplied hexagonal wrench to remove the four fixing screws (B) of dome cover (A).

2 Make screw holes and a cable hole in the cushioning sheet (D) that attaches to the back of the camera unit (C).

3Attach the cushioning sheet (double-sided tape) to the back of the camera unit.

4Align the camera unit with the surface of the ceiling, make marks

on the ceiling in the places where the screw holes are to be drilled, and then drill the four holes.

5 Cut a hole in the ceiling for routing the cables.

(I)

(J)

Note:

When routing the cables in the ceiling, use the accessory hexagonal

 

wrench (small) to loosen the cable cover fixing screw (E) at the rear

 

 

 

 

 

of the unit, and then remove the cable cover screw (F).

The following step differs only when installing the Model

VDC-D2184VA

Make a cable hole with a diameter of 73 mm.

4 English

Page 5
Image 5
Fisher VDC-D2184VA Installation, Coaxial cable type and maximum length, Installing the Model VDC-D1184VA