Fluke 5725A Access Procedures, A. Top View, B. Bottom View, Front, Lethal Voltage On Output

Models: 5725A

1 208
Download 208 pages 33.86 Kb
Page 120
Image 120
6-6. Access Procedures

5725A

Instruction Manual

6-6. Access Procedures

Figure 6-3 shows the location of all major modules in the 5725A. View A is a top view, and view B is a bottom view. Both views show the covers removed. The 5725A is constructed so that two modules are completely accessible from the top, and two modules are completely accessible from the bottom. Each of these four modules can be lifted out of the chassis and locked in a service position by pivoting the assembly and inserting two machined pegs into two machined holes in the chassis towards the center of the instrument. (Figure 6-4 shows the High Voltage Amplifier assembly (A3) in the Service position.) Once in the service position, a module can be removed completely by disconnecting all cables attached to it.

HIGH VOLTAGE

DIGITAL

INTERCONNECT

POWER

AMPLIFIER

SUPPLY

(A3)

(A5)

 

(A1)

(A4)

A. TOP VIEW

 

B. BOTTOM VIEW

 

FRONT

 

 

FRONT

 

 

VOLTAGE OUTPUT

 

 

 

 

 

SIGNAL

 

 

 

 

 

TRANSFORMER

 

 

 

 

CURRENT

 

 

 

HIGH

 

AMPLIFIER

WARNING

 

 

 

 

 

VOLTAGE

 

(A2)

LETHAL VOLTAGE ON OUTPUT

 

 

 

SENSE

 

 

TRANSISTOR HEAT SINKS AND

 

 

 

 

(A6)

 

 

MANY OTHER POINTS THROUGHOUT

 

 

 

 

 

THE CHASSIS.

 

 

 

 

 

 

 

 

 

POWER

 

 

 

 

TRANSFORMER

 

 

 

 

 

aq15f.eps

Figure 6-3. Assembly Location Diagram

6-6

Page 120
Image 120
Fluke 5725A Access Procedures, A. Top View, B. Bottom View, Front, Lethal Voltage On Output, Transistor Heat Sinks And