Introduction and Specifications 1

AC Current Specifications

Table 1-18. 5700A Series II AC Current Specifications: 99 % Confidence Level

 

5700A

 

 

 

 

 

 

99%

99 % Confidence Level

 

 

 

 

 

 

 

 

 

 

 

 

 

Range

Resolution

Frequency

 

 

Absolute Uncertainty

 

±5 °C from calibration temperature

 

 

 

 

 

 

 

 

 

 

For fields strengths >0.4 V/m but 3 V/m,

 

 

 

 

 

 

add 1 % of range.

Relative Uncertainty

±1 °C

24 Hours

Hz

90 Days

180 Days

±(ppm output + nA)

1 Year

24 Hours

90 Days

±(ppm output + nA)

220μA

2.2 mA

22 mA

1 nA

10 nA

100 nA

10

- 20

650

+ 30

20

- 40

350

+ 25

40

- 1 k

120

+ 20

1k - 5 k

500

+ 50

05k - 10 k

1500

+ 100

10

- 20

650

+ 50

20

- 40

350

+ 40

40

- 1 k

120

+ 40

1k - 5 k

500

+ 500

05k - 10 k

1500

+ 1000

10

- 20

650

+ 500

20

- 40

350

+ 400

40

- 1 k

120

+ 400

1k - 5 k

500

+ 5000

05k - 10 k

1500

+ 10,000

 

 

 

 

700 + 30

380 + 25

140 + 20

600 + 50

1600 + 100

700 + 50

380 + 40

140 + 40

600 + 500

1600 + 1000

700 + 500

380 + 400

140 + 400

600 + 5000

1600 + 10,000

750 + 30

410 + 25

150 + 20

650 + 50

1700 + 100

750 + 50

410 + 40

150 + 40

650 + 500

1700 + 1000

750 + 500

410 + 400

150 + 400

650 + 5000

1700 + 10,000

800 + 30

420 + 25

160 + 20

700 + 50

1800 + 100

800 + 50

420 + 40

160 + 40

700 + 500

1800 + 1000

800 + 500

420 + 400

160 + 400

700 + 5000

1800 + 10,000

450 + 30

270 + 25

110 + 20

450 + 50

1400 + 100

450 + 50

270 + 40

110 + 40

450 + 500

1400 + 1000

450 + 500

270 + 400

110 + 400

450 + 5000

1400 + 10,000

500 + 30

300 + 25

120 + 20

500 + 50

1500 + 100

500 + 50

300 + 40

120 + 40

500 + 500

1500 + 1000

500 + 500

300 + 400

120 + 400

500 + 5000

1500 +

10,000

Hz

±(ppm output + μA)

±(ppm output + μA)

220 mA

2.2 A

1μA

10 μA

10

- 20

650

+ 5

20

- 40

350

+ 4

40

- 1 k

120

+ 4

1k - 5 k

500

+ 50

05k - 10 k

1500

+ 100

020 - 1 k

600

+ 40

01 k - 5 k

700

+ 100

05 k - 10 k

8000

+ 200

700 + 5

380 + 4

150 + 4

600 + 50

1600 + 100

650 + 40

750 + 100

9000 + 200

750 + 5

410 + 4

170 + 4

650 + 50

1700 + 100

700 + 40

800 + 100

9500 + 200

800 + 5

420 + 4

180 + 4

700 + 50

1800 + 100

750 + 40

850 + 100

10,000 + 200

450 + 5

280 + 4

110 + 4

450 + 50

1400 + 100

600 + 40

650 + 100

7500 + 200

500 + 5

300 + 4

130 + 4

500 + 50

1500 + 100

650 + 40

750 + 100

8500 + 200

11 A

100μA

5725A Amplifier:

040 - 1 k

370

+ 170

400 + 170

440

+ 170

460

+ 170

01 k - 5 k

800

+ 380

850 + 380

900

+ 380

950

+ 380

05 k - 10 k

3000

+ 750

3300 + 750

3500

+ 750

3600

+ 750

300 + 170

700 + 380

2800 + 750

330 + 170

800 + 380

3200 + 750

Note: Maximum output from the calibrator’s terminals is 2.2 A. Uncertainty specifications for 220 μA and 2.2 mA ranges are increased by 1.3 x plus 2 μA when supplied through 5725A terminals. Specifications are otherwise identical for all output locations.

1-25

Page 41
Image 41
Fluke 5725A instruction manual 22 mA 10 nA 100 nA 650 350 120 1k 5 k 500 05k 10 k 1500

5725A specifications

The Fluke 5725A is a high-performance, multifunctional temperature calibration source designed to meet the demanding requirements of laboratory and industrial environments. Renowned for its accuracy, reliability, and versatility, the 5725A serves as a powerful tool for engineers and technicians engaged in temperature calibration processes.

At the core of the 5725A is its advanced measurement technology, which allows for precision temperature calibrations across a wide range. With an operating temperature range from -200°C to 660°C, it caters to various applications, making it suitable for calibrating thermocouples, resistance temperature detectors (RTDs), and other temperature measurement devices.

One of the standout features of the Fluke 5725A is its outstanding accuracy, boasting a specified uncertainty of just ±0.15°C. This level of precision ensures that users can maintain compliance with regulatory standards and regulatory requirements in fields such as aerospace, pharmaceuticals, and manufacturing.

The Fluke 5725A is equipped with dual-channel capabilities, allowing users to calibrate two devices simultaneously. This enhances productivity by minimizing downtime and optimizing workflow efficiency. The intuitive touchscreen interface simplifies operations, enabling users to view measurements, set up test parameters, and access historical data with ease.

Versatile connectivity options such as USB and Ethernet enable seamless integration into existing systems and allow for data transfer, remote control, and configuration. This feature empowers technicians to conduct calibrations efficiently, whether on-site or remotely.

The robust design of the Fluke 5725A ensures its durability in demanding environments. Built with high-quality materials, it is resistant to shocks and vibrations, making it suitable for use in manufacturing plants and laboratories where equipment may be subjected to harsh conditions.

Another notable characteristic of the 5725A is its ability to generate stable temperature outputs with minimal drift, contributing to consistency in calibration results. Its built-in self-test functionality helps ensure that the unit remains in peak operating condition, giving users confidence in their calibration processes.

In summary, the Fluke 5725A is a top-tier temperature calibration source that excels in accuracy, reliability, and user-friendliness. Whether in laboratory settings or industrial applications, its advanced technologies and features make it an essential tool for professionals tasked with maintaining precision in temperature measurements.