5725A Operating Functions and Modes

 

 

 

 

 

 

 

Operating Notes

3

 

 

 

 

 

 

 

5725A Operating Functions and Modes

3-9.

Current Standby

 

 

 

 

 

 

NO OUTPUT

 

 

 

 

 

BOOST

 

 

 

 

 

 

LIT

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT

SENSE

 

 

 

CURRENT

 

 

 

V ΩA

V ΩA

 

μ

 

OUTPUT

 

VOLTAGE MODE

NO

 

 

WIDEBAND

 

 

 

CURRENT MODE

HI

 

HI

 

 

HI

 

OUTPUT

 

 

 

 

 

 

5725A STANDBY

 

 

 

 

 

 

11A

 

 

LO

 

LO

 

 

 

MAX

FAULT

 

 

 

 

LO

 

 

 

 

 

 

 

 

OVERLOAD

 

 

 

 

 

 

 

2OV

 

 

 

 

 

 

 

PK

CABLE OFF

 

HI

 

 

 

 

 

MAX

 

 

 

 

 

 

 

 

 

AUX

GUARD

GROUND

 

 

 

 

 

CURRENT

 

 

 

 

 

 

 

 

 

 

aq10i.eps

 

Figure 3-5. Current Standby Mode

Current standby mode is when both CURRENT MODE and 5725A STANDBY indicators are lit. In current standby mode, the 5725A is not supplying an output. Current standby occurs under any of the following conditions:

When the 5700A current output location is set to "5725A", and any ac or dc current level is showing on the 5700A Output Display with the STANDBY annunciator lit.

If "5725A" is selected in a 5700A setup menu as the current amplifier, and any of the following conditions are true:

1.An ac or dc current 2.2A or above is showing on the 5700A Output Display with the STANDBY annunciator lit.

2.Any level of dc current is showing on the 5700A Output Display with the STANDBY annunciator lit, and the BOOST key on the 5700A is pressed so that the BOOST indicator is lit.

3.An ac current 1A or above is showing on the 5700A Output Display with the STANDBY annunciator lit, and the BOOST key on the 5700A is pressed so that the BOOST indicator is lit.

4.The 5700A is ranged locked on the 11A range, and any dc current or an ac current 1A or above is showing on the Output Display with the STANDBY annunciator lit.