Fluke T100/120/140
Technical Data
Technical Data
LED voltage range | 12... | 690V AC/DC |
LED resolution | ±12, 24, 50, 120, 230, | |
| 400, 690V | |
Tolerance | complying to DIN VDE | |
| 0682, Part 401 | |
LCD voltage range* | 12V... | 690V AC/DC |
LCD resolution* | 1V |
|
Tolerance* | ±(3% rdg. + 5 digits) | |
Voltage detection | automatic | |
Polarity detection | full range | |
Range detection | automatic | |
Response time | <0.1s LED / <2s LCD | |
Frequency range | 0...400Hz | |
Automatic load (RCD) | yes |
|
Internal basic load | approx. 2.1 W at 690V | |
Peak current | Is<0,3A(5s), In<3,5mA | |
Operation time | ED (DT) = 30s | |
Recovery time | 240 seconds | |
Auto Power On | <12 V AC/DC | |
|
| |
Voltage range | 100... | 690V AC |
Frequency range | 50... | 400Hz |
Resistance Measurement** | 0...1999Ω/1Ω | |
Tolerance** | ± (3 % rdg. + 10 | |
| digits) at 20 °C | |
Temperature coefficient: .... | ± 5 digits / 10 K | |
Test current** | <150µA | |
Overvoltage protection** .... | 690V AC/DC | |
Continuity Test | 0...400kΩ | |
Accuracy | RN +50% | |
Test current | < 5µA | |
Overvoltage protection | 690V AC/DC | |
Rotary Field Indication |
|
|
Voltage range (LEDs) | 100... | 690V |
Frequency range | 50... | 60Hz |
Measurement principle | ||
| Accessible electrode | |
Power supply | 2 x 1.5 V Micro IEC | |
| LR03 | |
Power consumption | max. 30mA / approx. | |
| 250mW | |
Temperature range | ||
Humidity | max. 85% relative | |
humidity |
|
|
Height above sea level | up to 2000 m | |
Measurement category | CAT IV / 600V | |
.......................................... | CAT III / 690V | |
Pollution degree | 2 |
|
Protection degree | IP65 | |
Safety complying to | DIN EN/IEC | |
| DIN VDE 0682 Part | |
| 401 (first DIN VDE | |
| 0680 Part 5, EN | |
| 61010, IEC 61010) | |
Weight | 180g (incl. batteries) | |
Dimensions (HxWxD) | 240 x 56 x 24mm |
*only T120,T140, T140VDE / ** only T140,T140VDE
13