Fluke T100/120/140

Technical Data

Technical Data

LED voltage range

12...

690V AC/DC

LED resolution

±12, 24, 50, 120, 230,

 

400, 690V

Tolerance

complying to DIN VDE

 

0682, Part 401

LCD voltage range*

12V...

690V AC/DC

LCD resolution*

1V

 

Tolerance*

±(3% rdg. + 5 digits)

Voltage detection

automatic

Polarity detection

full range

Range detection

automatic

Response time

<0.1s LED / <2s LCD

Frequency range

0...400Hz

Automatic load (RCD)

yes

 

Internal basic load

approx. 2.1 W at 690V

Peak current

Is<0,3A(5s), In<3,5mA

Operation time

ED (DT) = 30s

Recovery time

240 seconds

Auto Power On

<12 V AC/DC

Single-pole Phase Test

 

 

Voltage range

100...

690V AC

Frequency range

50...

400Hz

Resistance Measurement**

0...1999Ω/1Ω

Tolerance**

± (3 % rdg. + 10

 

digits) at 20 °C

Temperature coefficient: ....

± 5 digits / 10 K

Test current**

<150µA

Overvoltage protection** ....

690V AC/DC

Continuity Test

0...400kΩ

Accuracy

RN +50%

Test current

< 5µA

Overvoltage protection

690V AC/DC

Rotary Field Indication

 

 

Voltage range (LEDs)

100...

690V

Frequency range

50...

60Hz

Measurement principle

double-pole and

 

Accessible electrode

Power supply

2 x 1.5 V Micro IEC

 

LR03

Power consumption

max. 30mA / approx.

 

250mW

Temperature range

-10°C...55°C

Humidity

max. 85% relative

humidity

 

 

Height above sea level

up to 2000 m

Measurement category

CAT IV / 600V

..........................................

CAT III / 690V

Pollution degree

2

 

Protection degree

IP65

Safety complying to

DIN EN/IEC 61243-3,

 

DIN VDE 0682 Part

 

401 (first DIN VDE

 

0680 Part 5, EN

 

61010, IEC 61010)

Weight

180g (incl. batteries)

Dimensions (HxWxD)

240 x 56 x 24mm