FortiGate-5140 chassis

Shelf manager command line interface (CLI)

Figure 7: Connecting to a shelf manager serial port

SERIAL 2 (Secondary

Shelf Manager)

SERIAL1 (Primary

FortiGate-5140 Shelf Alarm Panel

Shelf Manager)

 

5140SAP

SERIAL 1

SERIAL 2

ALARM

RESET

MAJORMINOR USER1 USER2 USER3

 

 

 

CRITICAL

 

 

 

Fortinet RJ-45 to 9-pin Console Cable

To PC

RS-232

Console

Port

To connect to the shelf manager CLI using a shelf alarm panel serial port

1Connect the Fortinet console cable to the shelf alarm panel Serial 1 or Serial 2 port (see Figure 7).

2Connect the Fortinet console cable to your PC or other device RS-232 console port.

3Start a terminal emulation program (for example, HyperTerminal) on the management computer. Use these settings:

Baud Rate (bps)

9600

Data bits

8

Parity

None

Stop bits

1

Flow Control

None

4Press enter to connect to the CLI.

5At the login prompt enter the shelf manager user name and password. The default user name is root with no password.

When you log into the shelf manager CLI you are logging into a Linux shell as root. You can begin entering commands at the # prompt:

#

To add or change the shelf manager root account password

For enhanced security you should use the following steps to add a password for the shelf manager root account.

1At the # prompt enter the following Linux command to add a password for the root account:

# passwd

FortiGate-5140-R Chassis Guide

 

01-30000-87705-20090108

13

http://docs.fortinet.com/ Feedback

 

Page 13
Image 13
Fortinet 5140-R manual FortiGate-5140 Shelf Alarm Panel, To add or change the shelf manager root account password