Fortinet 5140-R manual Mounting the FortiGate-5140 chassis, Air flow

Models: 5140-R

1 32
Download 32 pages 13.58 Kb
Page 29
Image 29

FortiGate-5140 hardware procedures

Mounting the FortiGate-5140 chassis

FortiGate-5140 hardware procedures

This chapter assumes the chassis has been mounted and connected to a power source as detailed in “Power connection and configuration” on page 17.

This chapter discusses:

Mounting the FortiGate-5140 chassis

Inserting 5000-series modules into a FortiGate-5140 chassis

Using FortiSwitch-5003A and FortiSwitch-5003 boards for backplane communication

Mounting the FortiGate-5140 chassis

Note: Mount the FortiGate chassis before connecting power and installing the

FortiGate-5000 series modules.

The FortiGate-5140 chassis must be mounted in a standard 19-inch rack. The chassis requires 12U of vertical space in the rack.

If you install the FortiGate-5140 chassis in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient temperature. Make sure the operating ambient temperature does not exceed the manufacturer's maximum rated ambient temperature.

Caution: The FortiGate-5140 chassis should not be operated as a free-standing appliance.

Caution: Install the FortiGate-5140 chassis at the lower positions in the rack to avoid making the rack top-heavy and potentially falling over.

Air flow

For rack installation, make sure that the amount of air flow required for safe operation of the FortiGate-5140 chassis is not compromised.

Inserting 5000-series modules into a FortiGate-5140 chassis

You can insert FortiGate and FortiSwitch-5000 boards into the FortiGate-5140 chassis. Arrange the boards in slots as required for your configuration. FortiGate-5000 series boards can be installed in any FortiGate-5140 slots. FortiSwitch boards can only be installed in switch slots 1 and 2.

Your FortiGate-5140 chassis may have been shipped with temporary slot filler panels that include a warning message to read the FortiGate-5000 documentation before installing your product. The temporary slot fillers must be removed and all slots filled; either with FortiGate-5000 series boards or with air baffle slot fillers. Air baffle slot fillers are similar to blank FortiGate-5000 boards and are required for proper cooling air flow.

FortiGate-5140-R Chassis Guide

 

01-30000-87705-20090108

29

http://docs.fortinet.com/ Feedback

 

Page 29
Image 29
Fortinet 5140-R Mounting the FortiGate-5140 chassis, Inserting 5000-series modules into a FortiGate-5140 chassis, Air flow