Physical description of the |
For detailed information about connecting power to the
The power entry modules are hot swappable, which means you can remove and replace a defective PEM while the
The back panel also includes the back cable tray, an ESD socket and the chassis ground connector. The ground connector must be connected to Data Center ground (see “Connecting the
The back panel also contains 14 RTM slots numbered to correspond to the front panel slots. The RTM slots are available for
Physical description of the FortiGate-5140 chassis
The
Table 1:
Dimensions | 21 x 19 x 20.6 in. (53.3 x 48.3 x 52.4 cm) |
| (Height x Width x Depth) |
|
|
Shipping weight | 110 lb. (50 kg) |
completely assembled |
|
with packaging |
|
|
|
Operating environment | Temperature: 32 to 104°F (5 to 45°C) |
|
|
| Relative humidity: 5 to 85% |
|
|
Storage environment | Temperature: |
|
|
| Relative humidity: 5 to 85% |
|
|
Power consumption | Maximum: 2,980W DC |
|
|
Power input | 2x redundant |
| power feeds) |
FortiGate-5140 shelf managers
The
The shelf managers support redundant operation with automatic switchover. If both shelf managers are operating normally, one acts as the active shelf manager and the other as the standby. Usually the primary shelf manager would be the active shelf manager and the secondary shelf manager would be the standby shelf manager. The shelf managers monitor each other and either can trigger a switchover if necessary. The active shelf manager performs all shelf manager functions. If the active shelf manager fails or is removed, the standby shelf manager takes over all shelf manager functions.
FortiGate-5140-R Chassis Guide