1.7.5 Removing/Replacing Blower Assembly or Air Prover Switch

24G SERIES FLATBOTTOM GAS FRYERS CHAPTER 1: SERVICE PROCEDURES

1.7.4.2 Replacing Direct-Spark Ignitor Assembly (Units with Electronic Ignition Only)

1.Remove the burner shield from the burner-box slots.

2.Disconnect sense wire and ignition cable from the ignitor.

3.Remove the mounting screw from the ignitor mounting-bracket and remove the ignitor.

4.Reverse the procedure to replace the ignitor assembly. Ensure the ignitor is properly positioned in relation to the center burner before tightening mounting screw.

NOTE: The above procedure is applicable to fryers equipped with electronic ignition systems only.

Ensure ignitor is properly positioned (arrow) over the center burner prior to tightening the mounting screw.

1.7.5 Removing/Replacing Blower Assembly or Air Prover Switch

1.Remove back panel. On systems with built-in filtration, use care not to damage the oil-return heat-tape wiring insulation when removing backs (multi-batteried systems after 02/03 have two-piece back panels; remove both to access blower assembly).

Multi-batteried systems after 02/03 have upper and lower back panels, which must be removed to access the blower assembly (fryer above shown with upper back panel removed).