Frymaster 1824/2424G manual 24G SERIES FLATBOTTOM GAS FRYERS SERVICE PROCEDURES, 1-10

Models: 1824/2424G

1 76
Download 76 pages 52.64 Kb
Page 15
Image 15
1-10

24G SERIES FLATBOTTOM GAS FRYERS CHAPTER 1: SERVICE PROCEDURES

8.Remove the sensor bulb guard to access the probe and high-limit. Current production systems have a sensor bulb clamp that must be removed prior to removing the probe or high-limit from the frypot.

9.On the sensor bulb being removed, loosen and unscrew completely the compression nut, then the pass-through nut from the frypot. Carefully remove the sensor bulb from the frypot, being careful not to damage the remaining sensor bulb.

Temperature probe.

High-limit.

10.If removing the high-limit, remove the screws securing it to the wireway box. Mark and remove the wiring from the high- limit housing.

High-limit.

11.Reverse steps to install new temperature probe or high-limit. If reinstalling high-limit, ensure the capillary tube is properly routed around the temperature probe before tightening (see photo, Step #8). Reconnect wiring removed from defective high-limit.

1-10

Page 15
Image 15
Frymaster 1824/2424G manual 24G SERIES FLATBOTTOM GAS FRYERS SERVICE PROCEDURES, 1-10