1.7.6.2 Frypot/Firebox Removal/Replacement Procedure

24G SERIES FLATBOTTOM GAS FRYERS CHAPTER 1: SERVICE PROCEDURES

1.7.6.2 Frypot/Firebox Removal/Replacement Procedure

1.Perform Procedure 1.7.5, Removing/Replacing Blower Assembly or Air Prover Switch, Steps 1

– 4.

2.Disconnect the union at the gas valve. Remove four bolts connecting the burner manifold brackets to the burner box. Remove the burner manifold assembly and set aside.

3.Mark and disconnect drain-valve microswitch wiring. Remove elbow or drain-tee assembly, and then remove the drain valve/microswitch assembly.

1-16Manual background Disconnect union at gas valve and Manual backgroundremove four bolts (two per side) to remove burner manifold.

Remove drain elbow and drain valve assembly from the frypot.

Disconnect union at gas valve and remove four bolts connecting burner manifold brackets to firebox, elbow and drain valve assembly from frypot.

4.Remove two screws from control panel and lower, using care not to stretch or distort switch/indicator light wiring (if applicable). If control panel is equipped with switches (see Section 1.7.2, Removing/Replacing Rocker Switches, for detail), or indicator lights, mark and disconnect wiring and set control panel aside.

Note: If equipped with indicator lights, use a pin-pusher to remove pins from main-harness connector, and then remove control panel.

5.Perform Procedure 1.7.1, Remove/Replace Temperature Probe or High-Limit Thermostat, Steps 7 – 11.