1.1 Functional Description

24G SERIES FLATBOTTOM GAS FRYERS CHAPTER 1: SERVICE PROCEDURES

1.1 Functional Description

24G Series Flatbottom gas fryers contain a welded steel frypot (mild steel) with heat-transfer ducting on the frypot bottom for efficient heating of oil without scorching. A draft inducer draws air over the burners for combustion. Air movement directs the combustion products back and forth across the frypot bottom by means of a set of baffles, transferring the heat evenly. Cold air is prevented from entering the combustion chamber and cooling the oil during the coasting cycle.

Flames originate from orifices in three tubular burners positioned at the front and beneath the frypot. The diameter of the orifices differs for Natural (CE:G20/G25) and LP (CE:G31) gas as indicated in the table below.

NON-CE (Altitudes of 2000 feet or less)

MODEL

INPUT

GAS TYPE

ORIFICE

(BTU)

[DRILL SIZE (MM)]

 

 

 

 

 

 

1824/2424G

120

NAT

#34 (2.82)

LP

#50 (1.78)

 

 

 

 

 

 

ORIFICE

PART #

810-2051

810-2317

QTY

EQUIPMENT

PRESSURE

 

MBAR

INCH W.C.

3

10

4

3

27.5

11

 

 

 

CE ONLY (Altitudes of 2000 feet or less)

MODEL

INPUT

GAS TYPE

ORIFICE

(kW)

(MM)

 

 

 

 

 

 

 

30,0

G20

2,50

1824/2424G

(88,000

G25

2,50

 

BTU)

G31

1,60

 

 

 

 

ORIFICE

PART #

810-2628

810-2628

810-2317

QTY

EQUIPMENT

PRESSURE

 

MBAR

INCH W.C.

3

14,5

5,8

3

21,0

8,4

3

31,0

12,44

 

 

 

1-1