Fujitsu C141-E090-02EN manual Jumper setting of Cable Select, Example 1 of Cable Select

Models: C141-E090-02EN

1 189
Download 189 pages 54.01 Kb
Page 43
Image 43

2 4 6 8

1 3 5 7 9

CSEL connected to the interface cable selection can be done by the special interface cable.

Figure 3.16 Jumper setting of Cable Select

Figures 3.17 and 3.18 show examples of cable selection using unique interface cables.

By connecting the CSEL of the master device to the CSEL Line (conductor) of the cable and connecting it to ground further, the CSEL is set to low level. The device is identified as a master device. At this time, the CSEL of the slave device does not have a conductor. Thus, since the slave device is not connected to the CSEL conductor, the CSEL is set to high level. The device is identified as a slave device.

CSEL conductor

GND

Open

Host system

Master device

Slave device

Figure 3.17 Example (1) of Cable Select

CSEL conductor

GND

Open

Host system

Slave device

Master device

Figure 3.18 Example (2) of Cable Select

3 - 14

C141-E090-01EN

Page 43
Image 43
Fujitsu C141-E090-02EN manual Jumper setting of Cable Select, Example 1 of Cable Select