APPENDIX B

B.1 Test mode for maintenance

CAUTION: Please follow the procedure here or the offset data may be changed incor- rectly. If the scanner does not react as the procedure below, turn off the scanner and start from the beginning.

(1)Activating a test mode

Open the ADF cover and set the sensors to the following state before turning on the image scanner. The image scanner can be placed in the maintenance mode by pulling out the empty sensor lever and setting the B5 size sensor lever to down position with the ADF cover fully opened (see Figure below). If the image scanner is placed in the maintenance mode, the POWER lamp blinks. If the POWER lamp does not blink, turn off the power and try again. Then close the ADF.

(Setting of the ADF sensors for maintenance mode)

-Empty sensor: UP

-B5 size sensor: DOWN

B5 Size sensor

Empty sensor

DOWN

UP

ADF open

B – 1

Page 40
Image 40
Fujitsu M3093EX, M3093GX manual Appendix B, Test mode for maintenance